Elecrtic Iron and Power Cleaning Head Drop Test YW-1164 Standards: GB4706.7 Section 15.101 Special Requirements for Vacuum Cleaners and Water Suction Cleaning Appliances IEC60335-2-2 Section 15.101 Application: Mechanical Strength Test for Power Cleaner Heads of Water Suction Cleaning Appliances To assess the durability and robustness of Electric iron and Power Cleaner Heads of Water Suction when subjected to accidental drops. Test on: wet vacuum cleaner head Functionality: The basic structure of the power cleaner head drop tester consists of a device that suspends the power cleaning head of a suction cleaner in horizontal position and against a backing plate. Test Method: 1. Suspend the power cleaner head of the water suction cleaning appliance in a horizontal position relative to the base plate. 2. Drop an electric iron from a height o…